Creekside South Apartments

Unit 224 · 3400 McMillen Road, Wylie, TX, 75098

Service HVAC- Residential · Michael Estrada · 9/2/2026, 6:05:14 PM

READY TO CLOSEScore 60%
PASS

Notes quality

443 chars; verbs=true — Need to swap apt number on calls I worked on 224 first Found the system running owner had a list of parts to check verified the amp draw and was drawing 6 amps.

FAIL

Photos

0 photo signals (need 3 for service) [API proxy — warn only]

Fix: Attach at least 3 photos for this service job (before/after for coil cleaning / filter changes).

ServiceTitan API did not expose attachments; scored as warning until media endpoints are wired.

PASS

Parts

Parts/materials named in notes

PASS

Lead tech closeout

Lead: Michael Estrada

FAIL

Customer signature

No signature form/note signal [API proxy — warn only]

Fix: Collect customer signature on the job before marking complete.

Signature not API-confirmable yet; warning only until forms/attachments are wired.

Closeout notes / invoice summary
Need to swap apt number on calls I worked on 224 first Found the system running owner had a list of parts to check verified the amp draw and was drawing 6 amps. Tested capacitor checked okay. Tested windings and it was low. Tested compressor to ground and it checked okay. The compressor is bad due to the bypass being open causing the pressures be 175 low side and 330 on the high. Recommend a full system change out need to send a quote asap